Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Overload release current setting
800.0 - 2000A
Rated voltage
750 - 750V
Integrated earth fault protection
No
Rated permanent current Iu
2000A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive integrated
No
Number of poles
3
Type of control element
Push button
Motor drive optional
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Degree of protection (IP)
IP30
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA064713R1 | E3H 2000 PR123/DC IN=2000A 3P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Overload release current setting
800.0 .. 2000A
Rated voltage
750 .. 750V
Integrated earth fault protection
Rated permanent current Iu
2000A
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive integrated
Number of poles
3
Type of control element
Push button
Motor drive optional
Device construction
Built-in device slide-in technique (withdrawable)
Degree of protection (IP)
IP30
Adjustment range undelayed short-circuit release
3000.0 .. 30000A