Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Rated voltage
750 - 750V
Number of poles
3
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Overload release current setting
400.0 - 1000A
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Type of control element
Push button
Motor drive optional
Yes
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Rated permanent current Iu
1000A
From same serie
1SDA064707R1 | E3N 1000 PR123/DC IN=1000A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Rated voltage
750 .. 750V
Number of poles
3
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Overload release current setting
400.0 .. 1000A
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Type of control element
Push button
Motor drive optional
Complete device with protection unit
Degree of protection (IP)
IP30
Rated permanent current Iu
1000A
From same serie