Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Integrated earth fault protection
No
Overload release current setting
640.0 - 1600A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
4
With under voltage release
No
With switched-off indicator
Yes
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Rated voltage
1000 - 1000V
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Complete device with protection unit
Yes
Motor drive optional
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA064686R1 | E2B 1600 PR123/DC IN=1600A 4P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1600A
Integrated earth fault protection
Overload release current setting
640.0 .. 1600A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
4
With under voltage release
With switched-off indicator
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Rated voltage
1000 .. 1000V
Degree of protection (IP)
IP30
DIN rail (top hat rail) mounting optional
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Complete device with protection unit
Motor drive optional
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive integrated
From same serie