Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
4000A
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of poles
3
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
750 - 750V
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Motor drive optional
Yes
Type of control element
Push button
Overload release current setting
1600.0 - 4000A
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Suitable for DIN rail (top hat rail) mounting
No
From same serie
1SDA064663R1 | E6H 4000 PR122/DC IN=4000A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
4000A
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Number of poles
3
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
750 .. 750V
Degree of protection (IP)
IP30
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Motor drive optional
Type of control element
Push button
Overload release current setting
1600.0 .. 4000A
Number of auxiliary contacts as normally open contact
0
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Suitable for DIN rail (top hat rail) mounting
From same serie