Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Overload release current setting
320.0 - 800A
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Rated permanent current Iu
800A
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
Rated voltage
1000 - 1000V
Motor drive integrated
No
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA064627R1 | E3N 800 PR122/DC IN=800A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Overload release current setting
320.0 .. 800A
Number of auxiliary contacts as change-over contact
4
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Rated permanent current Iu
800A
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Number of poles
4
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Type of control element
Push button
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Rated voltage
1000 .. 1000V
Motor drive integrated
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Motor drive optional
From same serie