Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Rated voltage
1000 - 1000V
Overload release current setting
640.0 - 1600A
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Type of control element
Push button
Rated permanent current Iu
1600A
With switched-off indicator
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
Position of connection for main current circuit
Back side
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Complete device with protection unit
Yes
Number of auxiliary contacts as change-over contact
4
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA064612R1 | E3N 1600 PR122/DC IN=1600A 4P F

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Rated voltage
1000 .. 1000V
Overload release current setting
640.0 .. 1600A
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Type of control element
Push button
Rated permanent current Iu
1600A
With switched-off indicator
Motor drive optional
Degree of protection (IP)
IP30
Position of connection for main current circuit
Back side
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Complete device with protection unit
Number of auxiliary contacts as change-over contact
4