Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated voltage
750 - 750V
Rated permanent current Iu
2000A
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Type of electrical connection of main circuit
Bolt connection
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
No
Device construction
Built-in device fixed built-in technique
Overload release current setting
800.0 - 2000A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Yes
Number of poles
3
With switched-off indicator
Yes
Position of connection for main current circuit
Back side
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Degree of protection (IP)
IP30
Motor drive optional
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA064607R1 | E3H 2000 PR122/DC IN=2000A 3P F VR<HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
-kA
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated voltage
750 .. 750V
Rated permanent current Iu
2000A
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Type of electrical connection of main circuit
Bolt connection
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Device construction
Built-in device fixed built-in technique
Overload release current setting
800.0 .. 2000A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Complete device with protection unit
Number of poles
3
With switched-off indicator
Position of connection for main current circuit
Back side
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Degree of protection (IP)
IP30
Motor drive optional
From same serie