Technical specifications
Number of poles
3
Type of control element
None
Rated permanent current Iu
-A
Motor drive optional
No
Motor drive integrated
No
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
No
Suitable for intermediate mounting
No
Suitable for distribution board installation
Yes
Rated operation power at AC-3, 400 V
-kW
Degree of protection (NEMA)
1
Degree of protection (IP), front side
Other
Max. rated operation voltage Ue AC
1000V
Conditioned rated short-circuit current Iq
-kA
Rated operating voltage
1000 - 1000V
Rated short-time withstand current lcw
65kA
Rated operation power at AC-23, 400 V
-kW
Rated permanent current at AC-21, 400 V
-A
Version as emergency stop installation
No
Voltage release optional
No
Version as reversing switch
No
Version as maintenance-/service switch
Yes
Interlockable
No
Number of switches
-
Version as main switch
Yes
Version as safety switch
No
Suitable for front mounting 4-hole
No
Suitable for front mounting centre
No
Switching power at 400 V
-kW
Rated permanent current at AC-23, 400 V
-A
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SCA128583R1001 | OT3200E30
Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Number of poles
3
Type of control element
None
Rated permanent current Iu
-A
Motor drive optional
Motor drive integrated
Type of electrical connection of main circuit
Bolt connection
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Suitable for intermediate mounting
Suitable for distribution board installation
Rated operation power at AC-3, 400 V
-kW
Degree of protection (NEMA)
1
Degree of protection (IP), front side
Other
Max. rated operation voltage Ue AC
1000V
Conditioned rated short-circuit current Iq
-kA
Rated operating voltage
1000 .. 1000V
Rated short-time withstand current lcw
65kA
Rated operation power at AC-23, 400 V
-kW
Rated permanent current at AC-21, 400 V
-A
Version as emergency stop installation
Voltage release optional
Version as reversing switch
Version as maintenance-/service switch
Interlockable
Number of switches
-
Version as main switch
Version as safety switch
Suitable for front mounting 4-hole
Suitable for front mounting centre
Switching power at 400 V
-kW
Rated permanent current at AC-23, 400 V
-A