

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Suitable for intermediate mounting
No
Conditioned rated short-circuit current Iq
-kA
Rated short-time withstand current lcw
-kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Version as main switch
Yes
Version as reversing switch
No
Max. rated operation voltage Ue AC
750V
Rated permanent current at AC-23, 400 V
45A
Rated permanent current Iu
63A
Number of switches
1
Rated operating voltage
750 - 750V
Version as maintenance-/service switch
No
Version as safety switch
No
Rated permanent current at AC-21, 400 V
45A
Rated operation power at AC-23, 400 V
22kW
Suitable for floor mounting
No
Motor drive integrated
No
Device construction
Complete device in housing
Number of poles
6
Motor drive optional
No
Switching power at 400 V
22kW
Version as emergency stop installation
No
Voltage release optional
No
Suitable for front mounting centre
No
Type of control element
Long turning handle
Suitable for front mounting 4-hole
Yes
Interlockable
No
Suitable for distribution board installation
No
Colour control element
Red
Degree of protection (IP), front side
IP65
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SCA022401R7180 | OTP45BA6M

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Suitable for intermediate mounting
Conditioned rated short-circuit current Iq
-kA
Rated short-time withstand current lcw
-kA
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Version as main switch
Version as reversing switch
Max. rated operation voltage Ue AC
750V
Rated permanent current at AC-23, 400 V
45A
Rated permanent current Iu
63A
Number of switches
1
Rated operating voltage
750 .. 750V
Version as maintenance-/service switch
Version as safety switch
Rated permanent current at AC-21, 400 V
45A
Rated operation power at AC-23, 400 V
22kW
Suitable for floor mounting
Motor drive integrated
Device construction
Complete device in housing
Number of poles
6
Motor drive optional
Switching power at 400 V
22kW
Version as emergency stop installation
Voltage release optional
Suitable for front mounting centre
Type of control element
Long turning handle
Suitable for front mounting 4-hole
Interlockable
Suitable for distribution board installation
Colour control element
Red
Degree of protection (IP), front side
IP65
From same serie
We use cookies to enhance your experience.