Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
400.0 - 1000A
Adjustment range short-term delayed short-circuit release
600.0 - 600.0A
Rated voltage
690 - 690V
Rated permanent current Iu
1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
Motor drive integrated
No
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Number of poles
4
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
From same serie
1SDA059408R1 | E3S 1000 PR122/P-LSIG IN=1000A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
400.0 .. 1000A
Adjustment range short-term delayed short-circuit release
600.0 .. 600.0A
Rated voltage
690 .. 690V
Rated permanent current Iu
1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
Motor drive integrated
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Number of poles
4
With switched-off indicator
DIN rail (top hat rail) mounting optional
Motor drive optional
Degree of protection (IP)
IP30
From same serie