Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated permanent current Iu
1000A
Overload release current setting
400.0 - 1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
600.0 - 600.0A
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Type of control element
Push button
Rated voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
Yes
With switched-off indicator
Yes
Integrated earth fault protection
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA059280R1 | E2N 1000 PR122/P-LSIG IN=1000A 4

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated permanent current Iu
1000A
Overload release current setting
400.0 .. 1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
600.0 .. 600.0A
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Type of control element
Push button
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Degree of protection (IP)
IP30
Complete device with protection unit
Suitable for DIN rail (top hat rail) mounting
Motor drive optional
With switched-off indicator
Integrated earth fault protection
From same serie