Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
400.0 - 1000A
Rated permanent current Iu
1000A
Adjustment range short-term delayed short-circuit release
1000 - 10000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of poles
4
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Rated voltage
690 - 690V
Type of control element
Push button
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Degree of protection (IP)
IP30
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA059220R1 | E1N 1000 PR121/P-LSI IN=1000A 4P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
400.0 .. 1000A
Rated permanent current Iu
1000A
Adjustment range short-term delayed short-circuit release
1000 .. 10000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of poles
4
With switched-off indicator
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Rated voltage
690 .. 690V
Type of control element
Push button
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Degree of protection (IP)
IP30