Rated permanent current Iu
1000A
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
1000 - 10000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Integrated earth fault protection
No
Overload release current setting
400.0 - 1000A
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
Type of control element
Push button
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive optional
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
From same serie
1SDA059176R1 | E1B 1000 PR121/P-LSI IN=1000A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1000A
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
1000 .. 10000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Integrated earth fault protection
Overload release current setting
400.0 .. 1000A
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Type of control element
Push button
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive optional
Motor drive integrated
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0