Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1600A
Integrated earth fault protection
No
Adjustment range short-term delayed short-circuit release
1600 - 16000A
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
2400.0 - 24000A
DIN rail (top hat rail) mounting optional
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
With switched-off indicator
Yes
Type of control element
Push button
Overload release current setting
640.0 - 1600A
Motor drive optional
Yes
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Rated voltage
690 - 690V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA056609R1 | E3V 1600 PR121/P-LSI IN=1600A 3P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1600A
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
1600 .. 16000A
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
DIN rail (top hat rail) mounting optional
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
130kA
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
With switched-off indicator
Type of control element
Push button
Overload release current setting
640.0 .. 1600A
Motor drive optional
Degree of protection (IP)
IP30
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Rated voltage
690 .. 690V
From same serie