Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
2000A
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range short-term delayed short-circuit release
1200.0 - 1200.0A
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
Yes
DIN rail (top hat rail) mounting optional
No
With switched-off indicator
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
800.0 - 2000A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Degree of protection (IP)
IP30
Motor drive optional
Yes
Motor drive integrated
No
Complete device with protection unit
Yes
From same serie
1SDA056453R1 | E3H 2000 PR122/P-LSIG IN=2000A 3P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
2000A
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range short-term delayed short-circuit release
1200.0 .. 1200.0A
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
With switched-off indicator
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
800.0 .. 2000A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Degree of protection (IP)
IP30
Motor drive optional
Motor drive integrated
Complete device with protection unit
From same serie
We use cookies to enhance your experience.