Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
960.0 - 960.0A
Overload release current setting
640.0 - 1600A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Integrated earth fault protection
Yes
Rated voltage
690 - 690V
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Rated permanent current Iu
1600A
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Type of control element
Push button
Degree of protection (IP)
IP30
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Motor drive optional
Yes
From same serie
1SDA056431R1 | E3H 1600 PR123/P-LSIG IN=1600A 4P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
960.0 .. 960.0A
Overload release current setting
640.0 .. 1600A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Integrated earth fault protection
Rated voltage
690 .. 690V
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Rated permanent current Iu
1600A
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Type of control element
Push button
Degree of protection (IP)
IP30
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Motor drive optional
From same serie