Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Connection at separate chassis part
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Integrated earth fault protection
No
Rated permanent current Iu
800A
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Overload release current setting
320.0 - 800A
Number of auxiliary contacts as change-over contact
4
Number of poles
3
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Adjustment range short-term delayed short-circuit release
480.0 - 480.0A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Motor drive integrated
No
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive optional
Yes
Complete device with protection unit
Yes
From same serie
1SDA056356R1 | E3H 800 PR122/P-LSI IN=800A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Connection at separate chassis part
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Integrated earth fault protection
Rated permanent current Iu
800A
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Overload release current setting
320.0 .. 800A
Number of auxiliary contacts as change-over contact
4
Number of poles
3
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Adjustment range short-term delayed short-circuit release
480.0 .. 480.0A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Motor drive integrated
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive optional
Complete device with protection unit
From same serie