

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Integrated earth fault protection
No
Rated voltage
690 - 690V
Device construction
Built-in device fixed built-in technique
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Adjustment range short-term delayed short-circuit release
800 - 8000A
Suitable for DIN rail (top hat rail) mounting
No
Rated permanent current Iu
800A
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
320.0 - 800A
With under voltage release
No
DIN rail (top hat rail) mounting optional
No
Motor drive optional
Yes
Number of poles
4
Type of control element
Push button
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
With switched-off indicator
Yes
Position of connection for main current circuit
Back side
From same serie
1SDA056345R1 | E3H 800 PR121/P-LSI IN=800A 4P F HR

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Integrated earth fault protection
Rated voltage
690 .. 690V
Device construction
Built-in device fixed built-in technique
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Adjustment range short-term delayed short-circuit release
800 .. 8000A
Suitable for DIN rail (top hat rail) mounting
Rated permanent current Iu
800A
Type of electrical connection of main circuit
Bolt connection
Overload release current setting
320.0 .. 800A
With under voltage release
DIN rail (top hat rail) mounting optional
Motor drive optional
Number of poles
4
Type of control element
Push button
Complete device with protection unit
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
With switched-off indicator
Position of connection for main current circuit
Back side
From same serie
We use cookies to enhance your experience.