Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
Number of poles
4
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Overload release current setting
1280.0 - 3200A
Degree of protection (IP)
IP30
Rated permanent current Iu
3200A
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Adjustment range short-term delayed short-circuit release
1920.0 - 1920.0A
Motor drive optional
Yes
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
Integrated earth fault protection
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA056331R1 | E3S 3200 PR122/P-LI IN=3200A 4P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
Number of poles
4
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Overload release current setting
1280.0 .. 3200A
Degree of protection (IP)
IP30
Rated permanent current Iu
3200A
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Adjustment range short-term delayed short-circuit release
1920.0 .. 1920.0A
Motor drive optional
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Integrated earth fault protection
From same serie