Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
Number of auxiliary contacts as normally open contact
0
Overload release current setting
1280.0 - 3200A
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Adjustment range short-term delayed short-circuit release
1920.0 - 1920.0A
Integrated earth fault protection
No
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Rated permanent current Iu
3200A
Motor drive integrated
No
With switched-off indicator
Yes
Complete device with protection unit
Yes
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA056324R1 | E3S 3200 PR122/P-LSI IN=3200A 3P
Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
75kA
Number of auxiliary contacts as normally open contact
0
Overload release current setting
1280.0 .. 3200A
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
1920.0 .. 1920.0A
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Type of control element
Push button
Rated permanent current Iu
3200A
Motor drive integrated
With switched-off indicator
Complete device with protection unit
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30