Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Type of control element
Push button
Rated permanent current Iu
3200A
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
With switched-off indicator
Yes
Number of poles
3
Adjustment range short-term delayed short-circuit release
1920.0 - 1920.0A
Motor drive optional
Yes
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated voltage
690 - 690V
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Overload release current setting
1280.0 - 3200A
Motor drive integrated
No
From same serie
1SDA056164R1 | E3N 3200 PR122/P-LSI IN=3200A 3P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Type of control element
Push button
Rated permanent current Iu
3200A
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
With switched-off indicator
Number of poles
3
Adjustment range short-term delayed short-circuit release
1920.0 .. 1920.0A
Motor drive optional
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated voltage
690 .. 690V
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Overload release current setting
1280.0 .. 3200A
Motor drive integrated
From same serie
We use cookies to enhance your experience.