Technical specifications
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Rated voltage
690 - 690V
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Adjustment range short-term delayed short-circuit release
1500.0 - 1500.0A
With switched-off indicator
Yes
Rated permanent current Iu
2500A
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive optional
Yes
Overload release current setting
1000.0 - 2500A
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Motor drive integrated
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA056132R1 | E3N 2500 PR122/P-LSI IN=2500A 3P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Rated voltage
690 .. 690V
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
1500.0 .. 1500.0A
With switched-off indicator
Rated permanent current Iu
2500A
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive optional
Overload release current setting
1000.0 .. 2500A
Type of control element
Push button
Number of auxiliary contacts as normally closed contact
0
Degree of protection (IP)
IP30
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Number of poles
3
Motor drive integrated
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA