Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
2000A
Overload release current setting
800.0 - 2000A
Rated voltage
690 - 690V
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Adjustment range short-term delayed short-circuit release
1200.0 - 1200.0A
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Type of control element
Push button
Complete device with protection unit
Yes
Motor drive optional
Yes
DIN rail (top hat rail) mounting optional
No
Degree of protection (IP)
IP30
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA056039R1 | E2S 2000 PR123/P-LSIG IN=2000A 3

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
2000A
Overload release current setting
800.0 .. 2000A
Rated voltage
690 .. 690V
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Adjustment range short-term delayed short-circuit release
1200.0 .. 1200.0A
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
3
Type of control element
Push button
Complete device with protection unit
Motor drive optional
DIN rail (top hat rail) mounting optional
Degree of protection (IP)
IP30
Motor drive integrated