Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
2000A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
800.0 - 2000A
Integrated earth fault protection
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range short-term delayed short-circuit release
1200.0 - 1200.0A
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
With switched-off indicator
Yes
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Complete device with protection unit
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive optional
Yes
From same serie
1SDA056035R1 | E2S 2000 PR122/P-LI IN=2000A 3P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
2000A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
800.0 .. 2000A
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range short-term delayed short-circuit release
1200.0 .. 1200.0A
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
With switched-off indicator
Number of poles
3
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Complete device with protection unit
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive optional
From same serie