Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1600A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
640.0 - 1600A
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
DIN rail (top hat rail) mounting optional
No
Motor drive optional
Yes
Complete device with protection unit
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Rated voltage
690 - 690V
Number of poles
4
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Integrated earth fault protection
No
Adjustment range short-term delayed short-circuit release
1600 - 16000A
With switched-off indicator
Yes
From same serie
1SDA055912R1 | E2N 1600 PR121/P-LI IN=1600A 4P W M

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
1600A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
640.0 .. 1600A
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
DIN rail (top hat rail) mounting optional
Motor drive optional
Complete device with protection unit
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Rated voltage
690 .. 690V
Number of poles
4
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
1600 .. 16000A
With switched-off indicator
From same serie