Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated permanent current Iu
1600A
Overload release current setting
640.0 - 1600A
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Adjustment range short-term delayed short-circuit release
960.0 - 960.0A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
Number of poles
3
Motor drive optional
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive integrated
No
From same serie
1SDA055909R1 | E2N 1600 PR122/P-LSIG IN=1600A 3P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
65kA
Rated permanent current Iu
1600A
Overload release current setting
640.0 .. 1600A
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Adjustment range short-term delayed short-circuit release
960.0 .. 960.0A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Number of poles
3
Motor drive optional
Type of control element
Push button
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive integrated
From same serie
We use cookies to enhance your experience.