Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
2000A
Adjustment range short-term delayed short-circuit release
1200.0 - 1200.0A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
DIN rail (top hat rail) mounting optional
No
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
With switched-off indicator
Yes
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Complete device with protection unit
Yes
Overload release current setting
800.0 - 2000A
Motor drive integrated
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA055851R1 | E2B 2000 PR122/P-LI IN=2000A 4P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Rated permanent current Iu
2000A
Adjustment range short-term delayed short-circuit release
1200.0 .. 1200.0A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
DIN rail (top hat rail) mounting optional
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
With switched-off indicator
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Complete device with protection unit
Overload release current setting
800.0 .. 2000A
Motor drive integrated