Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
800.0 - 2000A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Adjustment range short-term delayed short-circuit release
2000 - 20000A
Rated permanent current Iu
2000A
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
4
Motor drive integrated
No
Type of control element
Push button
Complete device with protection unit
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
1SDA055849R1 | E2B 2000 PR121/P-LSI IN=2000A 4P

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
800.0 .. 2000A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Adjustment range short-term delayed short-circuit release
2000 .. 20000A
Rated permanent current Iu
2000A
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Type of electrical connection of main circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Suitable for DIN rail (top hat rail) mounting
Number of poles
4
Motor drive integrated
Type of control element
Push button
Complete device with protection unit
From same serie