Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
Rated permanent current Iu
1600A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
640.0 - 1600A
Adjustment range short-term delayed short-circuit release
1600 - 16000A
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Number of poles
3
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
From same serie
1SDA055810R1 | E2B 1600 PR121/P-LSIG IN=1600A 3P W

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Rated permanent current Iu
1600A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
640.0 .. 1600A
Adjustment range short-term delayed short-circuit release
1600 .. 16000A
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Number of poles
3
Integrated earth fault protection
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Motor drive integrated
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Type of control element
Push button
Degree of protection (IP)
IP30