Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
2520.0 - 6300A
Rated permanent current Iu
6300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 - 690V
Integrated earth fault protection
Yes
DIN rail (top hat rail) mounting optional
No
Adjustment range short-term delayed short-circuit release
3780.0 - 3780.0A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
9450.0 - 94500A
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Number of poles
4
Motor drive integrated
No
Motor drive optional
Yes
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
From same serie
1SDA055599R1 | E6H/F 6300 PR123/P-LSIG IN=6300A 4P W MP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Overload release current setting
2520.0 .. 6300A
Rated permanent current Iu
6300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 .. 690V
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
3780.0 .. 3780.0A
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
9450.0 .. 94500A
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Number of poles
4
Motor drive integrated
Motor drive optional
Complete device with protection unit
Degree of protection (IP)
IP30
From same serie