Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
No
System configuration TN
Yes
System configuration TN-C-S
No
Nominal discharge surge current (8/20)
20kA
System configuration TN-C
No
Max. continuous voltage DC
0V
System configuration IT
No
Number of conductors (without earthing)
2
Voltage protection level
2.6kV
Voltage protection level L-N
0kV
System configuration TT
No
Max. PV-voltage
0V
Construction size
2 modular spacing
Category type 2
Yes
Max. conductor cross section solid (solid, stranded)
25mm²
Leakage-current free
No
Max. continuous voltage AC
580V
Max. overcurrent protection device, series connection (fuse)
125A
With remote signalling contact
No
System configuration other
Yes
Nominal voltage AC
580V
Integrated backup fuse
No
Integrated short-circuit protection
No
Short-circuit breaking capacity (Isccr)
0kA
System configuration TN-S
Yes
Max. discharge surge current (8/20)
40kA
Degree of protection (IP)
IP20
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level N-PE
0kV
Nominal voltage DC
0V
Max. conductor cross section flexible (fine-strand)
35mm²
Integrated short-circuit protection selective to fuse gG
0A
Signalling at the device
Optic
Mounting method
DIN rail (top hat rail) 35 mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPCT2-580/2

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
System configuration TN
System configuration TN-C-S
Nominal discharge surge current (8/20)
20kA
System configuration TN-C
Max. continuous voltage DC
0V
System configuration IT
Number of conductors (without earthing)
2
Voltage protection level
2.6kV
Voltage protection level L-N
0kV
System configuration TT
Max. PV-voltage
0V
Construction size
2 modular spacing
Category type 2
Max. conductor cross section solid (solid, stranded)
25mm²
Leakage-current free
Max. continuous voltage AC
580V
Max. overcurrent protection device, series connection (fuse)
125A
With remote signalling contact
System configuration other
Nominal voltage AC
580V
Integrated backup fuse
Integrated short-circuit protection
Short-circuit breaking capacity (Isccr)
0kA
System configuration TN-S
Max. discharge surge current (8/20)
40kA
Degree of protection (IP)
IP20
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level N-PE
0kV
Nominal voltage DC
0V
Max. conductor cross section flexible (fine-strand)
35mm²
Integrated short-circuit protection selective to fuse gG
0A
Signalling at the device
Optic
Mounting method
DIN rail (top hat rail) 35 mm
From same serie