Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN
Yes
System configuration DC
No
System configuration TN-S
Yes
System configuration IT
Yes
System configuration TN-C-S
Yes
System configuration other
Yes
System configuration TT
Yes
Number of conductors (without earthing)
3
Nominal discharge surge current (8/20)
20kA
Nominal voltage AC
385V
Max. discharge surge current (8/20)
40kA
Max. continuous voltage AC
385V
Nominal voltage DC
0V
Voltage protection level L-N
0kV
Voltage protection level
1.8kV
Max. PV-voltage
0V
Max. continuous voltage DC
0V
Voltage protection level N-PE
0kV
System configuration TN-C
No
Integrated short-circuit protection
No
Max. overcurrent protection device, series connection (fuse)
125A
Max. overcurrent protection device, parallel connection (fuse)
0A
Mounting method
DIN rail (top hat rail) 35 mm
Integrated backup fuse
No
Short-circuit breaking capacity (Isccr)
0kA
Construction size
4 modular spacing
Max. conductor cross section solid (solid, stranded)
25mm²
Signalling at the device
Optic
Category type 2
Yes
Integrated short-circuit protection selective to fuse gG
0A
With remote signalling contact
No
Max. conductor cross section flexible (fine-strand)
35mm²
Degree of protection (IP)
IP20
Leakage-current free
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPCT2-385-3+NPE

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN
System configuration DC
System configuration TN-S
System configuration IT
System configuration TN-C-S
System configuration other
System configuration TT
Number of conductors (without earthing)
3
Nominal discharge surge current (8/20)
20kA
Nominal voltage AC
385V
Max. discharge surge current (8/20)
40kA
Max. continuous voltage AC
385V
Nominal voltage DC
0V
Voltage protection level L-N
0kV
Voltage protection level
1.8kV
Max. PV-voltage
0V
Max. continuous voltage DC
0V
Voltage protection level N-PE
0kV
System configuration TN-C
Integrated short-circuit protection
Max. overcurrent protection device, series connection (fuse)
125A
Max. overcurrent protection device, parallel connection (fuse)
0A
Mounting method
DIN rail (top hat rail) 35 mm
Integrated backup fuse
Short-circuit breaking capacity (Isccr)
0kA
Construction size
4 modular spacing
Max. conductor cross section solid (solid, stranded)
25mm²
Signalling at the device
Optic
Category type 2
Integrated short-circuit protection selective to fuse gG
0A
With remote signalling contact
Max. conductor cross section flexible (fine-strand)
35mm²
Degree of protection (IP)
IP20
Leakage-current free