Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
No
System configuration TN-C
No
System configuration TT
No
System configuration other
Yes
System configuration TN
Yes
System configuration TN-C-S
No
System configuration IT
No
Number of conductors (without earthing)
2
Max. continuous voltage AC
385V
Nominal discharge surge current (8/20)
20kA
Max. continuous voltage DC
0V
Short-circuit breaking capacity (Isccr)
0kA
Voltage protection level L-N
0kV
Integrated short-circuit protection
No
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level
1.8kV
Max. PV-voltage
0V
Nominal voltage AC
385V
Nominal voltage DC
0V
Mounting method
DIN rail (top hat rail) 35 mm
Max. overcurrent protection device, series connection (fuse)
125A
Voltage protection level N-PE
0kV
Max. discharge surge current (8/20)
40kA
Leakage-current free
No
Construction size
2 modular spacing
Degree of protection (IP)
IP20
Integrated backup fuse
No
Category type 2
Yes
With remote signalling contact
No
Integrated short-circuit protection selective to fuse gG
0A
Max. conductor cross section solid (solid, stranded)
25mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Signalling at the device
Optic
System configuration TN-S
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPCT2-385/2

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
System configuration TN-C
System configuration TT
System configuration other
System configuration TN
System configuration TN-C-S
System configuration IT
Number of conductors (without earthing)
2
Max. continuous voltage AC
385V
Nominal discharge surge current (8/20)
20kA
Max. continuous voltage DC
0V
Short-circuit breaking capacity (Isccr)
0kA
Voltage protection level L-N
0kV
Integrated short-circuit protection
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level
1.8kV
Max. PV-voltage
0V
Nominal voltage AC
385V
Nominal voltage DC
0V
Mounting method
DIN rail (top hat rail) 35 mm
Max. overcurrent protection device, series connection (fuse)
125A
Voltage protection level N-PE
0kV
Max. discharge surge current (8/20)
40kA
Leakage-current free
Construction size
2 modular spacing
Degree of protection (IP)
IP20
Integrated backup fuse
Category type 2
With remote signalling contact
Integrated short-circuit protection selective to fuse gG
0A
Max. conductor cross section solid (solid, stranded)
25mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Signalling at the device
Optic
System configuration TN-S
From same serie