Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration IT
Yes
System configuration DC
No
System configuration TN
Yes
System configuration TN-S
Yes
System configuration TN-C-S
No
System configuration TN-C
No
System configuration other
Yes
Number of conductors (without earthing)
1
Nominal voltage AC
280V
Max. discharge surge current (8/20)
40kA
Max. continuous voltage AC
280V
Max. continuous voltage DC
0V
Nominal discharge surge current (8/20)
20kA
Max. PV-voltage
0V
Voltage protection level L-N
0kV
System configuration TT
Yes
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level
1.4kV
Short-circuit breaking capacity (Isccr)
0kA
Max. overcurrent protection device, series connection (fuse)
125A
Construction size
2 modular spacing
Integrated short-circuit protection
No
Leakage-current free
No
Integrated backup fuse
No
Max. conductor cross section solid (solid, stranded)
25mm²
Mounting method
DIN rail (top hat rail) 35 mm
With remote signalling contact
No
Signalling at the device
Optic
Nominal voltage DC
0V
Max. conductor cross section flexible (fine-strand)
35mm²
Category type 2
Yes
Integrated short-circuit protection selective to fuse gG
0A
Voltage protection level N-PE
0kV
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
118 pcs
Zadar:
23 pcs
From same serie
SPCT2-280-1+NPE

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration IT
System configuration DC
System configuration TN
System configuration TN-S
System configuration TN-C-S
System configuration TN-C
System configuration other
Number of conductors (without earthing)
1
Nominal voltage AC
280V
Max. discharge surge current (8/20)
40kA
Max. continuous voltage AC
280V
Max. continuous voltage DC
0V
Nominal discharge surge current (8/20)
20kA
Max. PV-voltage
0V
Voltage protection level L-N
0kV
System configuration TT
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level
1.4kV
Short-circuit breaking capacity (Isccr)
0kA
Max. overcurrent protection device, series connection (fuse)
125A
Construction size
2 modular spacing
Integrated short-circuit protection
Leakage-current free
Integrated backup fuse
Max. conductor cross section solid (solid, stranded)
25mm²
Mounting method
DIN rail (top hat rail) 35 mm
With remote signalling contact
Signalling at the device
Optic
Nominal voltage DC
0V
Max. conductor cross section flexible (fine-strand)
35mm²
Category type 2
Integrated short-circuit protection selective to fuse gG
0A
Voltage protection level N-PE
0kV
Degree of protection (IP)
IP20
From same serie