Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C-S
No
Nominal voltage AC
175V
Integrated short-circuit protection
No
System configuration TN
Yes
System configuration TT
No
Category type 2
Yes
Short-circuit breaking capacity (Isccr)
0kA
With remote signalling contact
No
Max. continuous voltage AC
175V
Max. conductor cross section flexible (fine-strand)
35mm²
Construction size
4 modular spacing
Degree of protection (IP)
IP20
System configuration TN-S
No
Nominal discharge surge current (8/20)
20kA
Voltage protection level N-PE
0kV
Number of conductors (without earthing)
4
System configuration TN-C
No
Max. overcurrent protection device, series connection (fuse)
125A
Max. conductor cross section solid (solid, stranded)
25mm²
Max. PV-voltage
0V
Leakage-current free
No
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level
1kV
System configuration DC
No
Signalling at the device
Optic
Integrated short-circuit protection selective to fuse gG
0A
Voltage protection level L-N
0kV
System configuration other
Yes
Integrated backup fuse
No
Mounting method
DIN rail (top hat rail) 35 mm
System configuration IT
No
Max. discharge surge current (8/20)
40kA
Nominal voltage DC
0V
Max. continuous voltage DC
0V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPCT2-175/4

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C-S
Nominal voltage AC
175V
Integrated short-circuit protection
System configuration TN
System configuration TT
Category type 2
Short-circuit breaking capacity (Isccr)
0kA
With remote signalling contact
Max. continuous voltage AC
175V
Max. conductor cross section flexible (fine-strand)
35mm²
Construction size
4 modular spacing
Degree of protection (IP)
IP20
System configuration TN-S
Nominal discharge surge current (8/20)
20kA
Voltage protection level N-PE
0kV
Number of conductors (without earthing)
4
System configuration TN-C
Max. overcurrent protection device, series connection (fuse)
125A
Max. conductor cross section solid (solid, stranded)
25mm²
Max. PV-voltage
0V
Leakage-current free
Max. overcurrent protection device, parallel connection (fuse)
0A
Voltage protection level
1kV
System configuration DC
Signalling at the device
Optic
Integrated short-circuit protection selective to fuse gG
0A
Voltage protection level L-N
0kV
System configuration other
Integrated backup fuse
Mounting method
DIN rail (top hat rail) 35 mm
System configuration IT
Max. discharge surge current (8/20)
40kA
Nominal voltage DC
0V
Max. continuous voltage DC
0V
From same serie
We use cookies to enhance your experience.