Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
No
Number of conductors (without earthing)
3
Max. continuous voltage AC
175V
Max. PV-voltage
0V
Voltage protection level L-N
0kV
Nominal voltage DC
0V
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. continuous voltage DC
0V
Voltage protection level
1kV
System configuration TN-S
No
System configuration TT
No
Nominal discharge surge current (8/20)
20kA
System configuration TN
Yes
System configuration IT
No
System configuration other
Yes
Voltage protection level N-PE
0kV
Short-circuit breaking capacity (Isccr)
0kA
Max. overcurrent protection device, series connection (fuse)
125A
System configuration TN-C
No
System configuration TN-C-S
No
Nominal voltage AC
175V
Max. discharge surge current (8/20)
40kA
Integrated backup fuse
No
Integrated short-circuit protection
No
Leakage-current free
No
Integrated short-circuit protection selective to fuse gG
0A
Mounting method
DIN rail (top hat rail) 35 mm
With remote signalling contact
No
Signalling at the device
Optic
Max. conductor cross section solid (solid, stranded)
25mm²
Category type 2
Yes
Degree of protection (IP)
IP20
Construction size
3 modular spacing
Max. conductor cross section flexible (fine-strand)
35mm²
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPCT2-175/3

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
Number of conductors (without earthing)
3
Max. continuous voltage AC
175V
Max. PV-voltage
0V
Voltage protection level L-N
0kV
Nominal voltage DC
0V
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. continuous voltage DC
0V
Voltage protection level
1kV
System configuration TN-S
System configuration TT
Nominal discharge surge current (8/20)
20kA
System configuration TN
System configuration IT
System configuration other
Voltage protection level N-PE
0kV
Short-circuit breaking capacity (Isccr)
0kA
Max. overcurrent protection device, series connection (fuse)
125A
System configuration TN-C
System configuration TN-C-S
Nominal voltage AC
175V
Max. discharge surge current (8/20)
40kA
Integrated backup fuse
Integrated short-circuit protection
Leakage-current free
Integrated short-circuit protection selective to fuse gG
0A
Mounting method
DIN rail (top hat rail) 35 mm
With remote signalling contact
Signalling at the device
Optic
Max. conductor cross section solid (solid, stranded)
25mm²
Category type 2
Degree of protection (IP)
IP20
Construction size
3 modular spacing
Max. conductor cross section flexible (fine-strand)
35mm²
From same serie