Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
Number of conductors (without earthing)
4
System configuration TT
No
System configuration TN-C
No
System configuration IT
No
System configuration TN-C-S
No
Nominal discharge surge current (8/20)
20kA
System configuration other
Yes
Nominal voltage DC
0V
Max. continuous voltage DC
0V
Max. continuous voltage AC
135V
Nominal voltage AC
135V
Voltage protection level L-N
0kV
System configuration DC
No
Max. discharge surge current (8/20)
40kA
Max. PV-voltage
0V
Voltage protection level
0.8kV
System configuration TN-S
No
System configuration TN
Yes
Voltage protection level N-PE
0kV
Construction size
4 modular spacing
Max. overcurrent protection device, parallel connection (fuse)
0A
Integrated backup fuse
No
Max. overcurrent protection device, series connection (fuse)
125A
Leakage-current free
No
Integrated short-circuit protection
No
Short-circuit breaking capacity (Isccr)
0kA
Integrated short-circuit protection selective to fuse gG
0A
Max. conductor cross section solid (solid, stranded)
25mm²
Mounting method
DIN rail (top hat rail) 35 mm
With remote signalling contact
No
Signalling at the device
Optic
Category type 2
Yes
Degree of protection (IP)
IP20
Max. conductor cross section flexible (fine-strand)
35mm²
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPCT2-135/4

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
Number of conductors (without earthing)
4
System configuration TT
System configuration TN-C
System configuration IT
System configuration TN-C-S
Nominal discharge surge current (8/20)
20kA
System configuration other
Nominal voltage DC
0V
Max. continuous voltage DC
0V
Max. continuous voltage AC
135V
Nominal voltage AC
135V
Voltage protection level L-N
0kV
System configuration DC
Max. discharge surge current (8/20)
40kA
Max. PV-voltage
0V
Voltage protection level
0.8kV
System configuration TN-S
System configuration TN
Voltage protection level N-PE
0kV
Construction size
4 modular spacing
Max. overcurrent protection device, parallel connection (fuse)
0A
Integrated backup fuse
Max. overcurrent protection device, series connection (fuse)
125A
Leakage-current free
Integrated short-circuit protection
Short-circuit breaking capacity (Isccr)
0kA
Integrated short-circuit protection selective to fuse gG
0A
Max. conductor cross section solid (solid, stranded)
25mm²
Mounting method
DIN rail (top hat rail) 35 mm
With remote signalling contact
Signalling at the device
Optic
Category type 2
Degree of protection (IP)
IP20
Max. conductor cross section flexible (fine-strand)
35mm²
From same serie