Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C
No
System configuration TN
Yes
System configuration IT
No
System configuration TN-S
No
System configuration other
Yes
Nominal voltage DC
0V
System configuration TT
No
Max. discharge surge current (8/20)
40kA
Max. continuous voltage DC
0V
Nominal voltage AC
135V
Max. continuous voltage AC
135V
Nominal discharge surge current (8/20)
20kA
Number of conductors (without earthing)
2
Max. PV-voltage
0V
Voltage protection level
0.8kV
Max. overcurrent protection device, series connection (fuse)
125A
System configuration TN-C-S
No
Voltage protection level L-N
0kV
Integrated short-circuit protection selective to fuse gG
0A
Short-circuit breaking capacity (Isccr)
0kA
Mounting method
DIN rail (top hat rail) 35 mm
Integrated backup fuse
No
Voltage protection level N-PE
0kV
Construction size
2 modular spacing
Integrated short-circuit protection
No
Leakage-current free
No
System configuration DC
No
Max. overcurrent protection device, parallel connection (fuse)
0A
Signalling at the device
Optic
Category type 2
Yes
Max. conductor cross section solid (solid, stranded)
25mm²
With remote signalling contact
No
Degree of protection (IP)
IP20
Max. conductor cross section flexible (fine-strand)
35mm²
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPCT2-135/2

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C
System configuration TN
System configuration IT
System configuration TN-S
System configuration other
Nominal voltage DC
0V
System configuration TT
Max. discharge surge current (8/20)
40kA
Max. continuous voltage DC
0V
Nominal voltage AC
135V
Max. continuous voltage AC
135V
Nominal discharge surge current (8/20)
20kA
Number of conductors (without earthing)
2
Max. PV-voltage
0V
Voltage protection level
0.8kV
Max. overcurrent protection device, series connection (fuse)
125A
System configuration TN-C-S
Voltage protection level L-N
0kV
Integrated short-circuit protection selective to fuse gG
0A
Short-circuit breaking capacity (Isccr)
0kA
Mounting method
DIN rail (top hat rail) 35 mm
Integrated backup fuse
Voltage protection level N-PE
0kV
Construction size
2 modular spacing
Integrated short-circuit protection
Leakage-current free
System configuration DC
Max. overcurrent protection device, parallel connection (fuse)
0A
Signalling at the device
Optic
Category type 2
Max. conductor cross section solid (solid, stranded)
25mm²
With remote signalling contact
Degree of protection (IP)
IP20
Max. conductor cross section flexible (fine-strand)
35mm²
From same serie