Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
No
System configuration IT
No
System configuration TN-C-S
No
System configuration TN
Yes
System configuration TN-C
No
System configuration TN-S
No
System configuration other
Yes
System configuration TT
No
Max. continuous voltage AC
280V
Lightning impulse current (10/350 µs)
12.5kA
Number of poles
1
Max. continuous voltage DC
0V
Nominal voltage DC
0V
Nominal voltage AC
280V
Max. PV-voltage
0V
Voltage protection level
1.5kV
Voltage protection level L-PE
1.5kV
Voltage protection level L-N
0kV
Voltage protection level (DC+ - DC-)
0kV
Follow current extinguishing capability
0kA
Voltage protection level N-PE
0kV
Voltage protection level (DC+/DC- - PE)
0kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. overcurrent protection device, series connection (fuse)
160A
Specific energy (W/R)
39.1kJ/Ohm
Mounting method
On basic element
Construction size
1 modular spacing
Max. conductor cross section solid (solid, stranded)
25mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Remote signalling
No
Test class
Type 1 + 2
Signalling at the device
Optic
Integrated backup fuse
No
Energy-coordinated protection effect with regard to the terminal equipment
No
Voltage switching spark gap technology
No
Overcurrent protected voltage tapping
No
Degree of protection (IP)
IP20
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPBT12-280
Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration DC
System configuration IT
System configuration TN-C-S
System configuration TN
System configuration TN-C
System configuration TN-S
System configuration other
System configuration TT
Max. continuous voltage AC
280V
Lightning impulse current (10/350 µs)
12.5kA
Number of poles
1
Max. continuous voltage DC
0V
Nominal voltage DC
0V
Nominal voltage AC
280V
Max. PV-voltage
0V
Voltage protection level
1.5kV
Voltage protection level L-PE
1.5kV
Voltage protection level L-N
0kV
Voltage protection level (DC+ - DC-)
0kV
Follow current extinguishing capability
0kA
Voltage protection level N-PE
0kV
Voltage protection level (DC+/DC- - PE)
0kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Max. overcurrent protection device, series connection (fuse)
160A
Specific energy (W/R)
39.1kJ/Ohm
Mounting method
On basic element
Construction size
1 modular spacing
Max. conductor cross section solid (solid, stranded)
25mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Remote signalling
Test class
Type 1 + 2
Signalling at the device
Optic
Integrated backup fuse
Energy-coordinated protection effect with regard to the terminal equipment
Voltage switching spark gap technology
Overcurrent protected voltage tapping
Degree of protection (IP)
IP20
From same serie
We use cookies to enhance your experience.