Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN
Yes
System configuration TN-S
Yes
System configuration TN-C-S
No
System configuration DC
No
System configuration TN-C
Yes
System configuration TT
No
System configuration IT
No
Max. continuous voltage AC
280V
Nominal voltage DC
0V
Max. continuous voltage DC
0V
System configuration other
Yes
Max. overcurrent protection device, series connection (fuse)
125A
Voltage protection level L-N
0kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Nominal discharge surge current (8/20)
20kA
Nominal voltage AC
280V
Voltage protection level N-PE
0kV
Voltage protection level
1.4kV
Max. discharge surge current (8/20)
40kA
Integrated short-circuit protection selective to fuse gG
0A
Integrated short-circuit protection
No
Number of conductors (without earthing)
3
Short-circuit breaking capacity (Isccr)
0kA
Integrated backup fuse
No
Max. PV-voltage
0V
Leakage-current free
No
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
3 modular spacing
Degree of protection (IP)
IP20
With remote signalling contact
No
Max. conductor cross section flexible (fine-strand)
35mm²
Signalling at the device
Optic
Category type 2
Yes
Max. conductor cross section solid (solid, stranded)
25mm²
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
SPCT2-280/3

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN
System configuration TN-S
System configuration TN-C-S
System configuration DC
System configuration TN-C
System configuration TT
System configuration IT
Max. continuous voltage AC
280V
Nominal voltage DC
0V
Max. continuous voltage DC
0V
System configuration other
Max. overcurrent protection device, series connection (fuse)
125A
Voltage protection level L-N
0kV
Max. overcurrent protection device, parallel connection (fuse)
0A
Nominal discharge surge current (8/20)
20kA
Nominal voltage AC
280V
Voltage protection level N-PE
0kV
Voltage protection level
1.4kV
Max. discharge surge current (8/20)
40kA
Integrated short-circuit protection selective to fuse gG
0A
Integrated short-circuit protection
Number of conductors (without earthing)
3
Short-circuit breaking capacity (Isccr)
0kA
Integrated backup fuse
Max. PV-voltage
0V
Leakage-current free
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
3 modular spacing
Degree of protection (IP)
IP20
With remote signalling contact
Max. conductor cross section flexible (fine-strand)
35mm²
Signalling at the device
Optic
Category type 2
Max. conductor cross section solid (solid, stranded)
25mm²
From same serie
We use cookies to enhance your experience.