Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C
No
System configuration IT
No
System configuration TN-S
Yes
System configuration TN
Yes
System configuration TN-C-S
No
System configuration DC
No
System configuration TT
No
Lightning impulse current (10/350 µs)
12.5kA
System configuration other
Yes
Number of poles
1
Max. continuous voltage DC
0V
Max. continuous voltage AC
280V
Nominal voltage AC
280V
Max. PV-voltage
0V
Nominal voltage DC
0V
Voltage protection level
1.5kV
Voltage protection level L-PE
1.5kV
Follow current extinguishing capability
0kA
Voltage protection level (DC+ - DC-)
0kV
Voltage protection level (DC+/DC- - PE)
0kV
Voltage protection level N-PE
0kV
Max. overcurrent protection device, series connection (fuse)
160A
Specific energy (W/R)
39.1kJ/Ohm
Voltage protection level L-N
0kV
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
1 modular spacing
Max. overcurrent protection device, parallel connection (fuse)
0A
Integrated backup fuse
No
Signalling at the device
Optic
Overcurrent protected voltage tapping
No
Test class
Type 1 + 2
Degree of protection (IP)
IP20
Remote signalling
No
Energy-coordinated protection effect with regard to the terminal equipment
No
Max. conductor cross section solid (solid, stranded)
25mm²
Voltage switching spark gap technology
No
Max. conductor cross section flexible (fine-strand)
35mm²
Warehouse states
Zagreb:
57 pcs
Zadar:
37 pcs
From same serie
SPBT12-280/1

Details
- Earthing, lightning and surge protection
- Combined arrester for power supply systems
- 1 KOM
- EATON
Technical specifications
System configuration TN-C
System configuration IT
System configuration TN-S
System configuration TN
System configuration TN-C-S
System configuration DC
System configuration TT
Lightning impulse current (10/350 µs)
12.5kA
System configuration other
Number of poles
1
Max. continuous voltage DC
0V
Max. continuous voltage AC
280V
Nominal voltage AC
280V
Max. PV-voltage
0V
Nominal voltage DC
0V
Voltage protection level
1.5kV
Voltage protection level L-PE
1.5kV
Follow current extinguishing capability
0kA
Voltage protection level (DC+ - DC-)
0kV
Voltage protection level (DC+/DC- - PE)
0kV
Voltage protection level N-PE
0kV
Max. overcurrent protection device, series connection (fuse)
160A
Specific energy (W/R)
39.1kJ/Ohm
Voltage protection level L-N
0kV
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
1 modular spacing
Max. overcurrent protection device, parallel connection (fuse)
0A
Integrated backup fuse
Signalling at the device
Optic
Overcurrent protected voltage tapping
Test class
Type 1 + 2
Degree of protection (IP)
IP20
Remote signalling
Energy-coordinated protection effect with regard to the terminal equipment
Max. conductor cross section solid (solid, stranded)
25mm²
Voltage switching spark gap technology
Max. conductor cross section flexible (fine-strand)
35mm²