Details
- Earthing, lightning and surge protection
- Lightning current arrester for power supply systems
- 1 KOM
- ABB
Technical specifications
Degree of protection (IP)
IP20
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
8 modular spacing
Suitable for outdoor use
No
Max. continuous voltage AC
255V
Number of conductors (without earthing)
4
Signalling at the device
None
Max. continuous voltage DC
0V
Voltage protection level
2.5kV
Nominal voltage AC
230V
Voltage protection level L-N
2.5kV
Max. conductor cross section solid (solid, stranded)
50mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Integrated backup fuse
No
Nominal voltage DC
0V
With remote signalling contact
Yes
Voltage protection level N-PE
2.5kV
Nominal discharge surge current (8/20)
25kA
System configuration DC
No
System configuration TN
No
System configuration IT
No
System configuration TN-C
Yes
System configuration TT
No
System configuration TN-C-S
No
System configuration TN-S
Yes
System configuration other
No
Lightning impulse current (10/350 µs)
25kA
Exhausting
Yes
Follow current extinguishing capability
50kA
Specific energy (W/R)
-kJ/Ohm
Voltage protection level (DC+ - DC-)
0kV
Voltage protection level (DC+/DC- - PE)
0kV
Category type 1
Yes
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
2CTB815101R0800 | OVR T1 4L 25-255 TS

Details
- Earthing, lightning and surge protection
- Lightning current arrester for power supply systems
- 1 KOM
- ABB
Technical specifications
Degree of protection (IP)
IP20
Mounting method
DIN rail (top hat rail) 35 mm
Construction size
8 modular spacing
Suitable for outdoor use
Max. continuous voltage AC
255V
Number of conductors (without earthing)
4
Signalling at the device
None
Max. continuous voltage DC
0V
Voltage protection level
2.5kV
Nominal voltage AC
230V
Voltage protection level L-N
2.5kV
Max. conductor cross section solid (solid, stranded)
50mm²
Max. conductor cross section flexible (fine-strand)
35mm²
Integrated backup fuse
Nominal voltage DC
0V
With remote signalling contact
Voltage protection level N-PE
2.5kV
Nominal discharge surge current (8/20)
25kA
System configuration DC
System configuration TN
System configuration IT
System configuration TN-C
System configuration TT
System configuration TN-C-S
System configuration TN-S
System configuration other
Lightning impulse current (10/350 µs)
25kA
Exhausting
Follow current extinguishing capability
50kA
Specific energy (W/R)
-kJ/Ohm
Voltage protection level (DC+ - DC-)
0kV
Voltage protection level (DC+/DC- - PE)
0kV
Category type 1
From same serie
We use cookies to enhance your experience.