Technical specifications

Rated voltage

400V

Rated current

100A

Mounting method

DIN rail

Rated insulation voltage Ui

500V

Rated fault current

30A

Rated impulse withstand voltage Uimp

4kV

Leakage current type

AC

Number of poles

4

Selective protection

No

Short-circuit breaking capacity (Icw)

1kA

Short-time delayed tripping

No

Surge current capacity

0.25kA

Frequency

50/60 Hz

Additional equipment possible

Yes

With interlocking device

Yes

Pollution degree

2

Built-in depth

69mm

Degree of protection (IP)

IP2X

Ambient temperature during operating

-25 - 55°C

Width in number of modular spacings

4

Connectable conductor cross section multi-wired

0 - 35mm²

Connectable conductor cross section solid-core

35 - 35mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

Code: 1558117

2CSF204001R1900 | F204AC-100/0,03

Main Product Image

Code

1558117

Catalog number

F429167

Type

Residual current circuit breaker (RCCB)

Manufacturer

ABB

Serie

-

Neto WSP:

228,36

RP:285,45
* Minimum quantity1

Total stock:

0 PCS

Zadar0 PCS
Zagreb0 PCS

Details

  • Circuit breakers and fuses
  • Residual current circuit breaker (RCCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

400V

Rated current

100A

Mounting method

DIN rail

Rated insulation voltage Ui

500V

Rated fault current

30A

Rated impulse withstand voltage Uimp

4kV

Leakage current type

AC

Number of poles

4

Selective protection

Short-circuit breaking capacity (Icw)

1kA

Short-time delayed tripping

Surge current capacity

0.25kA

Frequency

50/60 Hz

Additional equipment possible

With interlocking device

Pollution degree

2

Built-in depth

69mm

Degree of protection (IP)

IP2X

Ambient temperature during operating

-25 .. 55°C

Width in number of modular spacings

4

Connectable conductor cross section multi-wired

0 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²