Aleta.hr
Main Product Image

2CDS284001R0401 | S204P-D40

Code: 1550697

ManufacturerRAZNO
Catalog number2CDS284001R0401
Type
EAN code4016779612562

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Release characteristic

D

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Concurrently switching neutral conductor

No

Current limiting class

3

Rated voltage

400V

Frequency

50 - 60Hz

Suitable for flush-mounted installation

No

Voltage type

AC

Over voltage category

3

Width in number of modular spacings

4

Built-in depth

69mm

Additional equipment possible

Yes

Connectable conductor cross section solid-core

0 - 25mm²

Pollution degree

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 - 55°C

Connectable conductor cross section multi-wired

0 - 16mm²

Rated current

40A

Number of protected poles

4

Flush-mounted installation

No

Explosion-proof

No

Power loss

25.6W


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS284001R0401 | S204P-D40

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Release characteristic

D

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Concurrently switching neutral conductor

Current limiting class

3

Rated voltage

400V

Frequency

50 .. 60Hz

Suitable for flush-mounted installation

Voltage type

AC

Over voltage category

3

Width in number of modular spacings

4

Built-in depth

69mm

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 25mm²

Pollution degree

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 16mm²

Rated current

40A

Number of protected poles

4

Flush-mounted installation

Explosion-proof

Power loss

25.6W

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.