Technical specifications

Release characteristic

C

Number of poles (total)

4

Number of protected poles

4

Rated current

6A

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Voltage type

AC

Concurrently switching neutral conductor

No

Width in number of modular spacings

4

Over voltage category

3

Suitable for flush-mounted installation

No

Pollution degree

3

Additional equipment possible

Yes

Built-in depth

69mm

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 - 55°C

Frequency

50 - 60Hz

Connectable conductor cross section solid-core

0 - 25mm²

Connectable conductor cross section multi-wired

0 - 16mm²

Rated voltage

400V

Explosion-proof

No

Flush-mounted installation

No

Power loss

8.8W


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS284001R0064 | S204P-C6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Number of poles (total)

4

Number of protected poles

4

Rated current

6A

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

12.5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Voltage type

AC

Concurrently switching neutral conductor

Width in number of modular spacings

4

Over voltage category

3

Suitable for flush-mounted installation

Pollution degree

3

Additional equipment possible

Built-in depth

69mm

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

0 .. 25mm²

Connectable conductor cross section multi-wired

0 .. 16mm²

Rated voltage

400V

Explosion-proof

Flush-mounted installation

Power loss

8.8W