2CDS282001R0317 | S202P-K3
Code: 1550447
Sign in or create an account for lower prices and other benefits
Sign in or create an account for lower prices and other benefits
Suitable for flush-mounted installation
No
Built-in depth
69mm
Release characteristic
K
Number of poles (total)
2
Number of protected poles
2
Rated current
3A
Rated voltage
400V
Rated insulation voltage Ui
440V
Rated impulse withstand voltage Uimp
4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
25kA
Voltage type
Other
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
25kA
Power loss
3.8W
Frequency
50 - 60Hz
Current limiting class
3
Flush-mounted installation
No
Concurrently switching neutral conductor
No
Over voltage category
3
Pollution degree
3
Additional equipment possible
Yes
Width in number of modular spacings
2.0
Degree of protection (IP)
IP20
Ambient temperature during operating
-25 - 55°C
Connectable conductor cross section multi-wired
0.75 - 16mm²
Connectable conductor cross section solid-core
0.75 - 25mm²
Explosion-proof
No
Zagreb:
0 pcs
Zadar:
0 pcs
Neto WSP:
1,04 €
RP:
1,30 €
Inventory:
60185 m
Neto WSP:
1,64 €
RP:
2,05 €
Inventory:
71438 m
Neto WSP:
0,89 €
RP:
1,11 €
Inventory:
2080 kg
Neto WSP:
0,30 €
RP:
0,38 €
Inventory:
32200 m
Neto WSP:
0,42 €
RP:
0,53 €
Inventory:
15950 m
HAUPA
Neto WSP:
1,31 €
RP:
1,64 €
Inventory:
846 pcs
TEM
Neto WSP:
3,34 €
RP:
4,18 €
Inventory:
3984 pcs
HAUPA
Neto WSP:
1,31 €
RP:
1,64 €
Inventory:
2195 pcs
EATON
Neto WSP:
3,66 €
RP:
4,58 €
Inventory:
1327 pcs
PITALARM
Neto WSP:
0,59 €
RP:
0,74 €
Inventory:
3340 pcs
PITALARM
Neto WSP:
0,72 €
RP:
0,90 €
Inventory:
578 pcs
LEGRAND
Neto WSP:
0,92 €
RP:
1,15 €
Inventory:
4083 pcs
Neto WSP:
0,63 €
RP:
0,79 €
Inventory:
65341 m
EATON
Neto WSP:
3,66 €
RP:
4,58 €
Inventory:
495 pcs
TEM
Neto WSP:
0,86 €
RP:
1,08 €
Inventory:
2352 pcs
Neto WSP:
0,66 €
RP:
0,83 €
Inventory:
5575 m
PITALARM
Neto WSP:
1,15 €
RP:
1,44 €
Inventory:
635 pcs
MGV VEDRIS
Neto WSP:
2,03 €
RP:
2,54 €
Inventory:
1112 pcs
Neto WSP:
0,25 €
RP:
0,31 €
Inventory:
17314 m
2CDS282001R0317 | S202P-K3
Total stock:
0 PCS
Suitable for flush-mounted installation
Built-in depth
69mm
Release characteristic
K
Number of poles (total)
2
Number of protected poles
2
Rated current
3A
Rated voltage
400V
Rated insulation voltage Ui
440V
Rated impulse withstand voltage Uimp
4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
25kA
Voltage type
Other
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
25kA
Power loss
3.8W
Frequency
50 .. 60Hz
Current limiting class
3
Flush-mounted installation
Concurrently switching neutral conductor
Over voltage category
3
Pollution degree
3
Additional equipment possible
Width in number of modular spacings
2.0
Degree of protection (IP)
IP20
Ambient temperature during operating
-25 .. 55°C
Connectable conductor cross section multi-wired
0.75 .. 16mm²
Connectable conductor cross section solid-core
0.75 .. 25mm²
Explosion-proof
We use cookies to enhance your experience.