![Main Product Image](https://assets.aleta.hr/415x415/9a77624e-dab3-4ca2-872b-6e3a41fa866f.webp)
![Main Product Image](https://assets.aleta.hr/415x415/9a77624e-dab3-4ca2-872b-6e3a41fa866f.webp)
Details
- Circuit breakers and fuses
- Miniature circuit breaker (MCB)
- 1 KOM
- ABB
Technical specifications
Release characteristic
B
Number of protected poles
1
Number of poles (total)
1
Rated insulation voltage Ui
440V
Rated impulse withstand voltage Uimp
4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
12.5kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
25kA
Frequency
50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
12.5kA
Rated voltage
230V
Suitable for flush-mounted installation
No
Concurrently switching neutral conductor
No
Over voltage category
3
Pollution degree
3
Built-in depth
68mm
Additional equipment possible
Yes
Width in number of modular spacings
4
Degree of protection (IP)
IP2X
Voltage type
AC/DC
Ambient temperature during operating
-25 - 55°C
Connectable conductor cross section multi-wired
0 - 16mm²
Connectable conductor cross section solid-core
0 - 25mm²
Current limiting class
3
Rated current
16A
Flush-mounted installation
No
Power loss
2.5W
Explosion-proof
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
2CDS281001R0165 | S201P-B16
![Main Product Image](https://assets.aleta.hr/300x300/b68f0439-8d71-4aad-b8e5-b9298076cb70_optimized.webp)
Details
- Circuit breakers and fuses
- Miniature circuit breaker (MCB)
- 1 KOM
- ABB
Technical specifications
Release characteristic
B
Number of protected poles
1
Number of poles (total)
1
Rated insulation voltage Ui
440V
Rated impulse withstand voltage Uimp
4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V
12.5kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V
25kA
Frequency
50 .. 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V
25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V
12.5kA
Rated voltage
230V
Suitable for flush-mounted installation
Concurrently switching neutral conductor
Over voltage category
3
Pollution degree
3
Built-in depth
68mm
Additional equipment possible
Width in number of modular spacings
4
Degree of protection (IP)
IP2X
Voltage type
AC/DC
Ambient temperature during operating
-25 .. 55°C
Connectable conductor cross section multi-wired
0 .. 16mm²
Connectable conductor cross section solid-core
0 .. 25mm²
Current limiting class
3
Rated current
16A
Flush-mounted installation
Power loss
2.5W
Explosion-proof
From same serie
We use cookies to enhance your experience.