Aleta.hr
Main Product Image

2CDS274001R0634 | S204M-C63

Code: 1550239

ManufacturerRAZNO
Catalog number2CDS274001R0634
Type
EAN code4016779544047
Additional quantity for delivery +820 kom
28.02.2025 + 1 pcs
05.03.2025 + 1 pcs
14.03.2025 + 818 pcs

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Release characteristic

C

Rated insulation voltage Ui

440V

Rated voltage

400V

Rated current

63A

Number of protected poles

4

Pollution degree

2

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Suitable for flush-mounted installation

No

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Over voltage category

3

Concurrently switching neutral conductor

No

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC/DC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Additional equipment possible

Yes

Width in number of modular spacings

4

Built-in depth

71mm

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 - 35mm²

Connectable conductor cross section multi-wired

0 - 25mm²

Ambient temperature during operating

-25 - 55°C


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS274001R0634 | S204M-C63

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Release characteristic

C

Rated insulation voltage Ui

440V

Rated voltage

400V

Rated current

63A

Number of protected poles

4

Pollution degree

2

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Suitable for flush-mounted installation

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Over voltage category

3

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC/DC

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Additional equipment possible

Width in number of modular spacings

4

Built-in depth

71mm

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.