Catalog number2CDS252001R0378
Type
EAN code4016779530736
Additional quantity for delivery +20 kom
05.02.2025 + 20 pcs

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC/DC

Suitable for flush-mounted installation

No

Width in number of modular spacings

2

Built-in depth

69mm

Rated current

6A

Rated voltage

400V

Release characteristic

Z

Ambient temperature during operating

-25 - 55°C

Connectable conductor cross section multi-wired

0 - 25mm²

Number of protected poles

2

Connectable conductor cross section solid-core

0 - 35mm²

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated insulation voltage Ui

440V

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Additional equipment possible

Yes

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Pollution degree

3

Concurrently switching neutral conductor

No

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Power loss

6.4W

Flush-mounted installation

No

Explosion-proof

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS252001R0378 | S202-Z 6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC/DC

Suitable for flush-mounted installation

Width in number of modular spacings

2

Built-in depth

69mm

Rated current

6A

Rated voltage

400V

Release characteristic

Z

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Number of protected poles

2

Connectable conductor cross section solid-core

0 .. 35mm²

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated insulation voltage Ui

440V

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Pollution degree

3

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Power loss

6.4W

Flush-mounted installation

Explosion-proof

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.