Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

16A

Number of poles (total)

4

Rated voltage

690V

Number of protected poles

4

Release characteristic

C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Additional equipment possible

Yes

Concurrently switching neutral conductor

No

Current limiting class

3

Built-in depth

82.5mm

Pollution degree

3

Frequency

50 - 60Hz

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Ambient temperature during operating

-25 - 60°C

Voltage type

AC/DC

Connectable conductor cross section multi-wired

0 - 70mm²

Over voltage category

4

Connectable conductor cross section solid-core

0 - 50mm²

Suitable for flush-mounted installation

No


Warehouse states

Zagreb:

2 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CCS894001R0164 | S804N-C16

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

16A

Number of poles (total)

4

Rated voltage

690V

Number of protected poles

4

Release characteristic

C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated insulation voltage Ui

690V

Rated impulse withstand voltage Uimp

8kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

36kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Additional equipment possible

Concurrently switching neutral conductor

Current limiting class

3

Built-in depth

82.5mm

Pollution degree

3

Frequency

50 .. 60Hz

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Ambient temperature during operating

-25 .. 60°C

Voltage type

AC/DC

Connectable conductor cross section multi-wired

0 .. 70mm²

Over voltage category

4

Connectable conductor cross section solid-core

0 .. 50mm²

Suitable for flush-mounted installation